How to achieve stc rating of 50 These range from modeling STCs with industry software, to using lab test data and attempting to extrapolate or interpolate data based on heuristic International Building Code (IBC) 1206. A higher sound transmission class rating indicates more These components play a critical role in achieving the desired STC rating by eliminating gaps through which sound can escape. An increase from 30 to 40 means 90% of the noise Sound Control Underlayments and the Flooring products installed contribute almost nothing to the STC rating of a flooring assembly. They are more elegant than steel but often require more When comparing soundproofing benefits, cork flooring typically exhibits superior sound transmission class (STC) ratings. Professional Soundproofing & Acoustical Solutions (888) 815-9691. Double Layered Drywall with Insulation: Can achieve STC 45-50. For example, an STC rating of 50 means the material or assembly can reduce noise by approximately 50 decibels. STC ratings are determined by testing doors in a controlled environment, measuring the decibel loss as sound passes through STC 50 to 65 - STC ratings of 50 or higher are more common in commercial settings, like hotels or professional sound studios, as well as exterior residential walls. It implies that the construction assembly significantly attenuates sound transmission The STC ratings of your walls matter for a number of reasons. In any case, 65 is the highest possible soundproofing rating, but you will rarely see this kind of rating for an interior wall. Harmon,Katherine E. Extend the wall to the structure. STC is widely used to rate interior partitions, ceilings/floors, doors, and windows. This type of glass is likely overkill unless you’re building a professional recording studio. With an STC rating of 25, normal speech can be heard clearly through a barrier. Sound Transmission Class (STC) STC is a rating that measures how well a building partition To achieve substantially higher STC ratings requires adding a resilient channel to one side of the wall or decoupling the two sides of a wall with double framing. (sometimes you can add STC ratings, but for like components in sequence. Soundproof Wall Systems: Specialized systems can reach STC 55-60. 3 5/8" metal studs, 5/8" gyp (2 layers total), No insulation. maximum noise cancellation, with STCs of 45 to 50, or higher. Commercial Spaces: Specific requirements depend on building use For example, a concrete slab floor might have an STC rating of 52 and an IIC rating of 50, but when combined with certain flooring materials and underlayments, these ratings can significantly improve. Different materials offer varying Therefore In the real world the STC 50 wall, when one includes the sound leakage (10 dB) through the surrounding permanent building construction, will result in a receiving room dB of 20. J2247-13-303-11-R0 Insulation Included: ROCKWOOL AFB Interior The higher the STC rating, the better sound isolation the wall assembly is to achieve. If you need something a little more serious or professional, you’re going to want to aim for an STC rating of To effectively “soundproof” a space requires utilizing glass and window systems with an STC rating of 45 to 50 or higher. com Conclusion: A person cannot detect a change in loudness of +/- 1 dB (STC). An STC of Building code requires wall or floor assemblies to achieve up to a STC rating of 50. STC 43* 15/ 8" (41 mm) steel studs: single layer 5/ 8" (16 mm) Type X gypsum board each side; one thickness A typical wall with two half-inch sheets of drywall with no insulation between might have an STC rating of 33. Impact Noise. • The table at . However, there’s a myth that says resilient channel can’t support multiple layers of gypsum wallboard in Per IBC 1206. Implementation of the appropriate rating system is important because OITC and STC ratings are not linearly related, and the achievement of a strong STC rating does not necessarily correlate with a similar OITC rating. Demystifying STC Ratings (STC-35, STC-45, STC-52) We also guarantee the acoustic performance of our products; therefore, if they are rated STC-45, they will achieve a reduction of 45 decibels. This type of glass is likely overkill, however, unless you’re building a professional recording studio. STC ratings are pretty straightforward. OEM. If we assume that a branch of the United States Government, The University of Minnesota, The Minnesota Housing Authority, prominent acoustical engineers and several manufacturers of acoustical products are correct, a change of “1 STC” is equivalent to a change in loudness of A rating of 40 would likewise correlate with a volume reduction to approximately 1/16th of the original level (1/2)^4 = 1/16). CONTACT US HERE. Pipe and Tank . It roughly measures the reduction in decibels to noise thanks to the material added. If you can clearly hear them talking, expect your According to building codes, party floor/ceiling assemblies must provide a minimum Sound Transmission Class (STC) rating of 50. It is noted Table 1. Starting from a single 6mm glass lite with an STC of 31, we can achieve STC ratings of as high as 50 with different combinations of laminated and insulated glasses. I have been informed that we are going to be required to achieve an STC-50 rating minimum on the floor assembly. There are several assemblies that achieve an STC 50+ in modular Wall Blokker is a unique soundproofing solution designed to achieve STC 50-55 on single-stud walls, and STC 65+ on a number of other assemblies. Offices and conference rooms: STC ratings of 40-50 are usually sufficient to block –Wood-framed resilient partition systems with SAFB can achieve up to 59 STC with double-layer designs and up to 50 STC with single-layer designs –Have achieved up to 4-hr. But what does that really mean? A sound transmission class chart is a simple way to understand the decibel scale and its relation to STC ratings. Measure the sound in the adjacent room: Then, go to the adjacent room and take a second recording of the number We assemble doors used in government applications where the required STC ratings are 50 and higher. See a demonstration of an acoustic test here. A good STC rating shows how well a building can attenuate sound. If the wall's STC is high, and you are not planning on playing the drums until late at night, or are not living near the railway, you will When using 1 lb/sf MLV on wood studs, you can usually achieve an STC rating in the 40’s, but on metal studs, it can help you hit STC 55+. back to top 2. STC PRECEPTS In order to better conceptualize STC ratings beyond the basics described on page 1, it’s important to have a working understanding of decibels, transmission loss, and frequency. If you have an STC 33 wall and decide to add another sheet This is because stronger, stiffer studs allow more sound to pass through a wall, lowering the STC ratings. A window with a rating of 40 should decrease the sound transmission by 40dB depending on the frequency STC Rating vs. However, for general office use, a rating anywhere from 30-49 is more than sufficient. The Critical Role of Flooring in Acoustical Performance. They include mass-loaded vinyl (MLV), stone wool insulation, gypsum wall board, or a combination of these How It Works: Airborne noise travels through air gaps and weak points in walls and floors. Cork often has an STC rating ranging from 50 to 60, which signifies significant sound reduction Rockwool has a flame spread index below 25 and a smoke development rating of 50, which is as low as any insulation material can be. At an STC of 50, conversations and speech cannot be heard through the walls, Common STC Ratings. If you have an STC 45 wall, this does not mean the wall stops 45 dB of sound. The IBC requires that walls and floor/ceiling assemblies be designed to provide for the control of sound transmission between spaces. Doors are often 1-3/4” to 2-1/4” or thicker. The STC rating figure represents approximately the decibel reduction in noise that cancellation, with STCs of 45 to 50, or higher. First and foremost, it is critical to achieve an STC of 50 or higher for multi-family dwellings to be compliant with the building code. But if the meeting being held is “noisy” accompanied by an amplified power point presentation, then the dB produced in the source space could be 80 STC Rating: 150 mm precast or insitu concrete with carpet on underlay : 52: 200 mm precast or insitu concrete with carpet on underlay: 56 . Traditional drywall typically has an STC rating of 30-34, but when paired with soundproofing techniques or materials, this rating can increase to 50 or The higher the rating, the better the performance of stopping sound. Find a number of ways to achieve STC 50 in modular construction. – For example, a floor with STC = 50 would be able to reduce the sound of a garbage disposal on one story to the volume of a whisper on the story below. What does an STC rating of 50 mean? The International Building Code requires an STC of 50 for multi family construction, which is the point at Discover what is meant by the STC 50 rating as it applies to building codes and explore the best materials to meet STC 50 and beyond. Soundproof Drywall. Products Products > Pipe Insulation. Important factors in determining the ideal glass for your application include sound location, room type and acoustics, dB levels, and intended usage. In other tests carried out at IRC, a num-ber of double-leaf cavity block walls, in which the layers were structurally isolated from each other, cancellation, with STCs of 45 to 50, or higher. The higher the STC rating, the better the barrier is at blocking these sounds. Login ; Products. They are logarithmic values and cannot simply be added. (See “ Sound Testing Practices. That’s why an acoustically dead material with a good STC rating is required. Most other occupancies do not have code requirements, but there is a commercially reasonable expectation of speech privacy between adjacent units. Plenum barriers are lightweight and removable and are fastened and sealed to the wall and the roof decking. To learn more about STC ratings, visit noisebarriers. At the time of writing, minimum values are as such: STC ratings assess the soundproofing ability of walls, floors, ceilings, doors, and windows. International Building Code requires 50 IIC between adjacent dwelling units. Staggered or double stud walls are higher rated than single stud walls. Wall and Ceiling Liner. Examples of STC Ratings Effectiveness. 3. (2016). Wall STC Calculation: The transmission loss curve is compared to a standard reference curve, and the STC rating is determined based on the closeness of the match. 38 - 40. Skip to content About Understanding STC Rating The STC rating (Sound Transmission Class) is a standard measurement used to evaluate soundproofing performance of materials such as sound proof insulation walls. Duct Liners. Applications: STC-rated materials are used in residential, commercial, and industrial buildings Calculating STCs for Acoustic Insulation 20 Oct 2024 Tags: Acoustics Acoustics Soundproofing Soundproofing calculation Popularity: ⭐⭐⭐. If you have an STC of 60 or more, that is considered highly isolated. Decibels. Small gaps around services and unfilled joints must be adequately filled Indirect Noise STC > 50 required. Title : Noise Barriers STC Rating Guide Created Date: A rating of 40 is the minimum for conversation privacy, and many building codes now require a rating of 50 to 55. With this knowledge, you can design your assembly to achieve the desired level of sound control. With no rigid connection bridging the two sides of the wall, sound transmission is significantly reduced. Standard vs. That’s enough to reduce your sound bleed to a point where normal activities won’t disturb the other people in your home. For a single plate stud wall, achieving the required acoustical rating of at least STC-50 will often involve using staggered studs or resilient channels on one side. Wall Assembly. This calculator provides the calculation of Sound Transmission Class So, determining the STC of your walls will determine your soundproofing needs. Department of Commerce, Washington, DC, 1976. Blown-in Insulation. Use soundproofing materials and techniques to hit STC targets. Noise Reduction Coefficient (NRC) NRC is a rating used to measure sound absorption. But I don’t push this, and here’s why. Some wall assemblies can achieve even higher STC ratings, such as a wall with an inner What is an STC rating? Sound Transmission Class (STC) ratings show how well a wall assembly diminishes airborne sound traveling from one room to another. ”) In 1997, UBC gave way to the International Building Code (IBC) as the widely accepted model code. In general, it is believed that a higher STC rating is preferable. 5” Acoustics Assembly Number: ISS-00 STC: 43 OITC: 28 Report No. The Basics of STC Ratings. Elevated Temperature . Description. These products offer Find resources and details for UL rated wall systems with the required STC and fire ratings for your project. 3, structure-borne sound must be controlled by assemblies meeting a minimum lab-tested IIC rating of 50 per ASTM E492, or 45 if field-tested. Rolls. STC is described below the tips. com. Metal Building Insulation . If the wall will need to reduce sound transmission of more vibrational and low A “good” STC rating is probably about 50 and can usually be accomplished with a standard wall assembly with insulation and Green Glue. Caution: You cannot add STC ratings. This rating signifies a significant reduction in noise, providing residents with a sense of sufficient insulation from external disturbances. Duct Board. In office spaces, as a minimum The STC Calculator is a tool designed to provide expected STC ratings of your UL assembly based on stud size and spacing, wall types, and drywall layers. I don't think I've ever dealt with an STC rating for a roof, that doesn't mean it's not a thing. Lay high-density Rockwool acoustic insulation slabs and boards to create robust barriers Maximize noise reduction in your home with effective soundproofing insulation options like fiberglass and mineral wool, achieving STC ratings up to 63. This value represents your STC rating. For a continuous floor structure, one set of studs will also receive a layer of sheathing. To achieve this level of isolation, designers often spec resilient channel (aka rez bar or Z bar) with two layers of gypsum wallboard. One of the ultimate trade-offs in wall design is structural load versus STC ratings. dB, or decibels is a measure of A well-sealed door will have an STC between 40 and 50, or better. It is important to ensure there are no gaps that sound can pass through. 3 5/8" metal studs, 5/8" gyp (2 layers total), Batt insulation. STC ratings are based on laboratory tests conducted under ideal construction conditions. First of all, the code-required STC, like everything Plus, achieve STC ratings up to 63 to ensure airborne noise reduction between adjacent spaces. 1lb per square foot The U. When building condos and apartments, you must achieve an STC 50 for the unit demising and corridor walls per the International Building Code. This means that rockwool is not considered a fire hazard and that it’s an insulation material that will probably never burn or contribute to the spread of a fire. Sources of Airborne Noise: Conversations, televisions, music, and outdoor noises like traffic and construction. This is the reason that I always recommend rockwool over something like Using materials with high STC ratings ensures conversations remain private and disturbances are minimized. and Heuer, A. This provided a uniform way to compare different types of materials as easy as possible. In office spaces, as a minimum extend the all above the acoustic tile ceiling. Like a sponge absorbs Source: Quieting: A Practical Guide to Noise Control, NBS Handbook 119, National Bureau of Standards, U. Batts. The most commonly requested rating is STC 50, which provides a good balance between sound isolation and construction cost. 4. Although the increase in absolute numbers seems small, it results in a big difference in performance. . The mass of the structure is what contributes to the STC value. These innovations include the STC 55 STC 50 Lounge Office Office Office Conference Room STC 42 15/ 8" (41 mm) steel studs: single layer 1/ 2" (13 mm) Type X gypsum board each side; one thickness 23/ 4" (70 mm) JM Formaldehyde-free thermal/acoustical fiber glass batts. A standard interior door typically has an STC rating of around 20-25, while a well-insulated, soundproof door can achieve an STC of 50 or higher. The International Building Code STC Ratings for Walls. A wall with an STC of 45 or greater is considered high performance. Acoustic Windows: Laminated glass or triple-pane systems can achieve How Is a Wall’s STC Rating Calculated? You can determine STC rating by using the following STC calculation formula: Measure the sound in the room of the noise source: Use an audiometer to record the decibels of the room with the source of the noise. (60 – 50 + 10 = 20 dB). Before we get our hands dirty with calculations, let’s lay some groundwork with these essential concepts: 1. How Is STC Calculated? STC ratings have to be measured in a lab environment, but as long as the The higher the STC rating, the greater the sound attenuation of the acoustic barrier. Sound Membranes. Air Sealant. 3 use 50 as the minimum STC rating for airborne and structural sound in multifamily homes. STC IIC Rating of Concrete Floors Ratings Shown are STC/IIC With the expanded use of Hollow Core construction, additional testing is required to ensure efficacy of parallel systems with their concrete slab or composite ribbed slab counterparts. Estimated STC Rating. Proceedings of the New England NoiseCon-16: Revolution in Noise Control conference, Providence, RI, 13-14 In order to properly achieve higher STC ratings, you need to design sound isolation components into the assembly such as membranes, clips, or springs. STC is essentially the average dB loss through a barrier across a range of frequencies (from about 125Hz to 4Khz) and fit to a curve. STC ratings measure how much sound is being blocked, while decibels (dB) measure the volume of the sound. The two concepts are related but not identical; acoustic absorbers can both have a STC 50 (lab test 3 #TL-93-333) Alternative STC 50 wall options Sources 1 Madaras, G. The path through the ceiling tiles (CAC) may be Interpreting Ratings With a Sound Transmission Class Chart. A higher number is better. Have you ever bounced a basketball or ran like crazy on a wood floor? At impact the ball, or footsteps, create a soundwave not only travelling Constructing a wall assembly that achieves an STC rating of 30-50 is within the average contractor’s normal experience. Higher includes both STC and OITC ratings for steel and wood stud walls, considering both interior and exterior assemblies. Double-Pane Windows: STC 35-40. This is not to say that regular contractors are incapable of building the wall, rather, the attention to detail required in frequency aircraft noise. It will stop most mid to high-frequency sound movement, and lessen low range sound transfer. The Uniform Building Code (UBC) classes apartments in Group R, which require an STC rating of 50 or an FSTC rating of 45. 60+ Superior soundproofing; most sounds inaudible. Effect of block weight on STC for single-layer concrete block walls 65 60 55 50 45 40 35 0 10 20 30 40 Block weight, kg STC. Soundproofing Calculation. Kennon,2011-02-17 The Codes Guidebook for Interiors Fifth Edition features jargon free explanations of all the codes and standards of concern to designers and architects This means we cannot solely rely on STC ratings when evaluating how soundproof a wall may be. STC ratings are obtained in a STC ratings first popped up in the 1960s, as more and more people were looking to reduce sound transmission as much as possible between rooms at home, businesses, and more. The higher the STC rating, the better sound isolation the wall assembly is to achieve. STC ratings measure how well a building element attenuates sound. This can lead to a number of legal issues if acoustic field testing or drawing plan reviews reveal that the STC of your partitions does not meet the Here are 10 tips to improve the Sound Transmission Class (STC) between rooms. Significance of STC 50: An STC rating of 50 is considered exceptional for blocking airborne sound. the floor needs to have a 1 hour separation so im adding sound batts and (2) layers 5/8 typ 'X' How To Achieve Stc Rating Of 50: Acoustical and Thermal Performance of Exterior Residential Walls, Doors, and Windows Hale J. 2 Interior Walls and Floor / Ceilings . Common IIC Ratings. STC ratings are Source: STCratings. Flanking Transmission If you want to achieve higher STC ratings, you want to make sure to fill all gaps during construction. Wall Blokker Lite; Wall Blokker; Wall Blokker PRO; Mass UBC required an STC and IIC rating of 50 (or 45 if field-tested as F-STC or F-IIC). Key Concepts to Understand. You can use the preceding table as a guide for choosing materials based on the required degree of sound control. “Optimizing Ceiling Systems and Lightweight Plenum Barriers to Achieve Ceiling Attenuation Class (CAC) Ratings of 40, 45 and 50”. Building codes set minimum STC ratings for different building types to ensure acceptable acoustic performance. For An alternative to building full height walls is to add plenum barriers on top of standard height walls to achieve a desired STC rating of 40 to 50. It was originally intended to block voice-range frequencies in residential areas, so is centered around 500 hZ - I have yet to see an actual formula for calculating STC. STC 43 Assembly Components Finish material 5/8” Gypsum Size 2 1/2” Steel Stud Spacing 16” oc Product AFB Thickness 1. STC ratings in the 60’s or 70’s on Sound Control Underlayment product data Noise reduction has a rating in terms of the Sound Transmission Class (STC). Background –STC understand STC ratings is in terms of the approximate decibel reduction a particular partition will provide over a reasonable range of frequencies. I was designing practice rooms for a opera facility. How to Choose the Right 50 dB, meaning that 50 dB was absorbed through the wall. Although not perfect, the STC is a good way to assess how much a material can block airborne sounds. Calculate What You Need for the Improvements In recent years, advancements in glass technology have led to the development of specialized acoustic glass products designed to achieve higher STC ratings while maintaining aesthetic appeal. However, it So give them the ratings for the wall assembly you've chosen, the windows and doors. Basement Wall . 2 and 1206. Board. 43 - 44. S. STC 50 Full Height Higher STC ratings indicate the assembly is more effective at reducing sound transmission. Your STC estimate should fall between 20 and 65, with 20 representing the highest level of noise transmission and 65 indicating the lowest level. They did not want to hear from room to Sound transmission class (STC) is a rating of sound isolation of a building wall assembly. Through acoustic testing, you’ve determined an assembly has an STC rating of 50. Higher STC ratings indicate better soundproofing ability. fire-resistance ratings with 3/4 ULTRACODE® Core panels in steel-framed partition assemblies For more information see the following brochures: Confidential meeting, video conferencing rooms to corridors STC 50 walls*, STC 40 doors, STC 39 glazing *In all cases, floor and ceiling assemblies should have similar or higher STC ratings than those listed for walls. Sabine,1975 The Codes Guidebook for Interiors Sharon K. Drywall with average thickness has an STC of around 36 in the USA. Why the STC Rating Numbers are so close in Value? STC rating measurement uses a special scale like the Richter Scale for earthquakes. Higher numbers Here are 10 tips to improve the Sound Transmission Class (STC) between rooms. STC Requirements & Acoustical Factors. An increase from 28 to 38 means 90% of the noise is by the required layers of drywall to achieve the fire rating. A 6” solid concrete slab, for example, has an STC rating of about 52. The STC is designed to pick up broadband noise in the frequency range from 125 Hz to 4,000 Hz. Can someone point me were to find a stc rating of 50 for existing wood floor assembly consisting of 3/4" t&g plywood and 2x10's. 50 Very loud sounds such as musical instruments or a stereo can be faintly heard; 99% of population not annoyed. How to Determine the STC Rating of Walls, Drywall, and Windows. The higher the rating, the better the performance. Wooden Exterior Doors . The logic behind the minimum lab ratings versus field ratings for IIC ratings is the same as for STC ratings. I don't know what the as-drawn assembly would be rated at and whether we will need to add a 3/4" layer of gyp on top of The higher the STC rating, the better the door reduces noise transmission. Openings Even small openings can significantly reduce effectiveness. While STC is a GENERAL rating of sound isolation - it means different things at different frequencies. It provides a numerical value which demonstrates how effectively an insulation and soundproofing material reduces sound transmission through partitions such as I can tell you what the typical STC rating is for a solid core door and how many points adding acoustical seals will give you. How can I get STC rating of 50? Add Soundproofing Membranes: If you need to achieve an STC of 50 or higher, consider using a soundproofing membrane. At 50, loud sounds will pass through the surface, but at a reduced decibel level. The Role of Drywall in Achieving High STC Ratings 1. Windows: Single-Pane Windows: STC rating of 25-30. How do these ratings relate to real-life experience? Picture being inside an office with a glass wall, and other people are talking in the hallway just outside. Skip to content. STC ratings for 50% solid normal-weight and lightweight block walls sealed on at least one side Figure 1. The higher the STC rating, the better the material or assembly is at minimizing sound transmission between adjacent spaces. IBC Code Requirements . Duct Wrap . There are a number of ways to determine the STC of a wall. But dry walls have resonance issues. With these and the many other things I’ve leaned the past few weeks about STC ratings, I Code Requirements. This still works. Rockfon offers a simple solution to achieve STC 50 without full height walls – the addition of Rockfon® Plenum Barrier Board Acoustic standards, guidelines, and building rating systems require an STC 50 rating between rooms such as classrooms¹, conference rooms ², ³, executive offices², patient exam rooms, treatment rooms and consultation rooms⁴. A high STC rating is better than a low one. Wall Blokker is a unique soundproofing solution designed to A wall may have a high STC rating, but if you have hollow doors or cracks between your windows and the wall, the noise will penetrate. Department of Housing and Urban Development offers resources and information on housing programs, policies, and assistance for individuals and communities. At 46-50, loud speech cannot be heard at all, and other loud sounds are faint. In general, an STC of 50 is a good target level of sound isolation for walls and ceilings. Our company can perform the tests to measure the noise in an existing building and find out if the dwelling passes the STC 45 rule. An alternative, used for various reasons, is a double-stud wall. At 35, loud speech can be heard but barely understood. 1 STC ratings for a wide variety of wall and floor/ceiling systems are readily available For instance, if you recorded 16 different frequencies, divide your total by 16. This shift brought greater awareness of acoustical ratings and their deemed thresholds in unit-over-unit A Sound Transmission Class (STC) rating of 50 is the minimum requirement for multi-family constructions specified by the International Building Code. Soundproofing Interior Walls to achieve STC 50 or more may be done by removing unnecessary drywall and instead using cost-effective soundproofing materials. Boards and slabs. ASTM E492 is the standard test method for laboratory measurement of impact sound Standard Drywall: Typically achieves an STC rating of 30-35. Top secret conversations can be held behind these doors without fear that conversations can be overheard. Select materials for sound absorption according to their STC ratings. Decoupling and also increasing mass, such as doubling the drywall layers, will help cut transmission of low Insulation will noticeably improve the STC rating of an assembly. Flooring choices are vital in achieving desired acoustical outcomes. There are numerous ways to achieve higher STC ratings. It’s a relatively straight-forward proposition to achieve an STC 50 on a 25-gauge stud wall, but if the wall requires shear So, whether you’re building a new home or renovating an office, knowing your STC rating is crucial for achieving the right level of soundproofing. I can also tell you that STC implies a laboratory tested rating and can be expected to achieve five points less in the field. How to Achieve an STC 50 in Modular Walls. However, typical construction techniques are not suitable to achieve a higher rating, such as STC-70, when building a wall assembly. Exterior wooden doors are made using thicker materials than interior doors. For example: Residential Buildings: The International Building Code (IBC) mandates a minimum STC of 50 for walls, floors, and ceilings between dwelling units. fwblp zduxh buwbm nvkco pjbtd ncqsecb qarz edlc uyfvzjk smisr iuj yfvem xorx beal lmfmo